{"id":154102,"date":"2024-05-02T11:13:59","date_gmt":"2024-05-02T15:13:59","guid":{"rendered":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/?p=154102"},"modified":"2025-05-02T14:44:34","modified_gmt":"2025-05-02T18:44:34","slug":"impeedasense-wearable-electrode-device","status":"publish","type":"post","link":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/impeedasense-wearable-electrode-device\/","title":{"rendered":"ImpeedaSense Wearable Electrode Device"},"content":{"rendered":"\n<p><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Problem Statement <\/h2>\n\n\n\n<p>Falls experienced in hospitals are common and dangerous. Patients are at an especially high risk of experiencing a fall during trips to the bathroom [1]. Bladder bioimpedance can be used to quantify a patient&#8217;s bladder fullness. Monitoring of this information allows a caregiver to help the patient to the restroom without them needing to ask for assistance. <\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Purpose<\/h2>\n\n\n\n<p>Our proposal centers on designing a comfortable and non-intrusive device to measure bladder impedance, determining an individual&#8217;s bladder fullness and reducing patient falls. Based on research, the team found that a tetrapolar electrode system could be a viable solution for electrode configurations to ensure the best signal acquired. It suggests that the best placement for electrodes have two placed on the hips (M3 &amp; M4), and two placed next to the navel (S1 &amp; S2) [2, 3, 4].<\/p>\n\n\n\n<p class=\"has-text-align-center\"><img decoding=\"async\" src=\"https:\/\/lh7-us.googleusercontent.com\/lv0ysCdQD71JlcffNCZ1Lm4CS_dgdXSmQgnmE0MNSYTeFQkersDVDvqC60emvU2SG20kCFtdDFOHwy80vP2LkBlrHOnCE_kNrrn1SG-Kg_EP6-6VaY2yY0bYzjlfW54a8ndvnbY-qSMQJiM=s2048\" style=\"width: 500px;\"><\/p>\n\n\n\n<p><img decoding=\"async\" src=\"https:\/\/lh7-us.googleusercontent.com\/lv0ysCdQD71JlcffNCZ1Lm4CS_dgdXSmQgnmE0MNSYTeFQkersDVDvqC60emvU2SG20kCFtdDFOHwy80vP2LkBlrHOnCE_kNrrn1SG-Kg_EP6-6VaY2yY0bYzjlfW54a8ndvnbY-qSMQJiM=s2048\" style=\"width: 5px;\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Design &amp; Overall System <\/h2>\n\n\n\n<p>The image below highlights 1) how the device is worn, 2) how the device records the bladder impedance and 3) the belt structure. <\/p>\n\n\n\n<p class=\"has-text-align-center\"><img decoding=\"async\" src=\"https:\/\/lh7-us.googleusercontent.com\/8OMLhpUJChyc5GXHFwftafgUk35v-WAbAtZHW2HDJbTVXRHJdfRecIdsCrsZYekj3BT47fW8gz6GJeXtd9zPYkCNQkUvqcLJg_ybDis9ZaiJf8id2YB1ITuYyKLzGgOudOFoicEq6WAVcEE=s2048\" style=\"width: 700px;\"><\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Design Considerations<\/h2>\n\n\n\n<p>The table emphasizes key components and reasonings behind our design choices. The main focus of our wearable belt is to provide a comfortable interface while also maintaining the ability to adjust for various body sizes. <\/p>\n\n\n\n<figure class=\"wp-block-table\"><table><tbody><tr><td class=\"has-text-align-center\" data-align=\"center\"><strong>Belt Component<\/strong><\/td><td class=\"has-text-align-center\" data-align=\"center\"><strong>Features and Purpose<\/strong><\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Main Body<\/td><td class=\"has-text-align-center\" data-align=\"center\">Cushioning: Prevent pressure ulcers<br>Seatbelt: Provide structure<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Nylon Cover<\/td><td class=\"has-text-align-center\" data-align=\"center\">Waterproof<br>Sanitizable<br>Non-irritating<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Back Fastener<\/td><td class=\"has-text-align-center\" data-align=\"center\">Snap buttons: Flat and comfortable to lay on for extended period of time<br>Multiple snap holes: Provide further adjustability for overall fit<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Elastic Connectors&nbsp;<\/td><td class=\"has-text-align-center\" data-align=\"center\">Comfortable adjustment between hip and navel electrodes&nbsp;<\/td><\/tr><tr><td class=\"has-text-align-center\" data-align=\"center\">Electrode Leads\/Holes<\/td><td class=\"has-text-align-center\" data-align=\"center\">Four electrode holes: Placement of four leads for accurate signal collectionMultiple navel lead holes: Provides flexibility<\/td><\/tr><\/tbody><\/table><\/figure>\n\n\n\n<h2 class=\"wp-block-heading\">Final Prototype<\/h2>\n\n\n\n<p>The images below show the final belt design as well as the computer setup to collect data.<\/p>\n\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"812\" src=\"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2024\/05\/IMG_1708-2-1024x812.jpg\" alt=\"\" class=\"wp-image-170102\" style=\"width:415px;height:auto\" srcset=\"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2024\/05\/IMG_1708-2-1024x812.jpg 1024w, https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2024\/05\/IMG_1708-2-300x238.jpg 300w, https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2024\/05\/IMG_1708-2-768x609.jpg 768w, https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2024\/05\/IMG_1708-2-1536x1218.jpg 1536w, https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2024\/05\/IMG_1708-2-2048x1625.jpg 2048w, https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2024\/05\/IMG_1708-2-1920x1523.jpg 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n<div class=\"wp-block-image\">\n<figure class=\"aligncenter size-large is-resized\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"936\" src=\"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2024\/05\/IMG_1710-1024x936.jpg\" alt=\"\" class=\"wp-image-170112\" style=\"width:543px;height:auto\" srcset=\"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2024\/05\/IMG_1710-1024x936.jpg 1024w, https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2024\/05\/IMG_1710-300x274.jpg 300w, https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2024\/05\/IMG_1710-768x702.jpg 768w, https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2024\/05\/IMG_1710-1536x1403.jpg 1536w, https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2024\/05\/IMG_1710-2048x1871.jpg 2048w, https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2024\/05\/IMG_1710-1920x1754.jpg 1920w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n<\/div>\n\n\n<h2 class=\"wp-block-heading\">Conclusion<\/h2>\n\n\n\n<p>Our process suggests that the design of our wearable electrode belt is sound. We were able to demonstrate bioimpedance trends similar to those described in the literature. With future investigation and improvements, our device could be very beneficial for increasing patient safety and establishing a more proactive approach in fall prevention.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Future Improvements<\/h2>\n\n\n\n<p>Our device provides a substantial first step in the development of this product. However, with the following improvements listed below, our device could be more fully functional and wearable in its intended clinical setting. <\/p>\n\n\n\n<p><strong>Condensed Circuitry<\/strong>: Currently, an external bioimpedance processing chip and computer is used to gather our impedance values. This chip and computer ideally would be condensed into a microchip and incorporated into the belt. Additionally, including potential bluetooth capabilities to transfer the signal externally could help monitor patients.<\/p>\n\n\n\n<p><strong>Sizing<\/strong>: Multiple iterations of the belt will be developed at various sizes to accommodate all patients.<\/p>\n\n\n\n<p><strong>Alarm System<\/strong>: Using the bioimpedance signal, the next vital step would be to create an alarm system that would notify the provider when a patient needs assistance.<\/p>\n\n\n\n<p><br><strong>Advanced Calibration: <\/strong>Different people have different bathroom needs based on water intake, electrolytes, diet, or \u2018an anxious bladder\u2019 which affect the accuracy of the device. Ideally the device should work for all patients.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Acknowledgements<\/h2>\n\n\n\n<p>We would like to thank Dr. Ganeshan, Kaveri Salunke, and Dr. Seidman for their aid in our project. We would also like to thank the personnel at Curbell Medical. Including Donald Gibson, Garrett Mattimore, Thomas Kennedy, Kelly O\u2019Connor and specifically Dan Macdonald, for sending us materials as well as assisting us along the project.<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">Customer<\/h2>\n\n\n\n<p class=\"has-text-align-center\"><img decoding=\"async\" src=\"https:\/\/lh7-us.googleusercontent.com\/sKVs7N9yB7z-U3m5LZmnBw3pWi9bQqnhK78bd5SQ45ZNLpmxgsW_dXAZPeweAdfzsTjhoydY0Y9zw7gg4_0eM9aKfCr8mAJw7RXDQ_-8XNGu7Nwb2y74Xp_I-04lpI5fHqoCayjnoVgX5dg=s2048\" style=\"width: 300px;\"><\/p>\n\n\n\n<p>Led by Donald Gibson, Thomas Kennedy, Dan MacDonald, Garrett Mattimore and Kelly O&#8217;Connor. <\/p>\n\n\n\n<h2 class=\"wp-block-heading\">The Team<\/h2>\n\n\n\n<figure class=\"wp-block-image size-large\"><img loading=\"lazy\" decoding=\"async\" width=\"1024\" height=\"273\" src=\"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2024\/05\/image-12-1024x273.png\" alt=\"\" class=\"wp-image-170182\" srcset=\"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2024\/05\/image-12-1024x273.png 1024w, https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2024\/05\/image-12-300x80.png 300w, https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2024\/05\/image-12-768x205.png 768w, https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2024\/05\/image-12.png 1274w\" sizes=\"auto, (max-width: 1024px) 100vw, 1024px\" \/><\/figure>\n\n\n\n<p class=\"has-text-align-center\">Nick Dente, Kate Isaac, Lam Nguyen, Fiorella Rivadeneira, Isabella Smith<\/p>\n\n\n\n<p class=\"has-text-align-center\">Faculty Supervisor: Dr. Veena Ganeshan<\/p>\n\n\n\n<p class=\"has-text-align-center\">Project Management Liasion: Kaveri Salunke<\/p>\n\n\n\n<h2 class=\"wp-block-heading\">References<\/h2>\n\n\n\n<p>1. D. Gibson and T. Kennedy, \u201cCurbell Medical &#8211; Wearable electrode system for bladder bioimpedance measurement,\u201d <em>BME 295 Course Materials, Pitch Videos, University of Rochester Blackboard<\/em><\/p>\n\n\n\n<p>2. D. Leonh\u00e4user et al., \u201cEvaluation of electrical impedance tomography for determination of urinary bladder volume: comparison with standard ultrasound methods in healthy volunteers,\u201d BioMedical Engineering OnLine, vol. 17, no. 1, Jul. 2018.<\/p>\n\n\n\n<p>3. Y. Yang and J. Wang, &#8220;New Tetrapolar Method for Complex Bioimpedance Measurement: Theoretical Analysis and Circuit Realization,&#8221; 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference, Shanghai, 2005, pp. 6605-6607.<\/p>\n\n\n\n<p>4. H. Yoon et al., \u201cBladder Volume Measurement With Electrical Impedance Analysis In Spinal Cord-Injured Patients,\u201d American Journal of Physical Medicine &amp; Rehabilitation, vol. 77, no. 6, Nov. 1998.<\/p>\n\n\n\n<p><\/p>\n","protected":false},"excerpt":{"rendered":"<p>Problem Statement Falls experienced in hospitals are common and dangerous. Patients are at an especially high risk of experiencing a fall during trips to the bathroom [1]. Bladder bioimpedance can&hellip;<\/p>\n","protected":false},"author":6242,"featured_media":0,"comment_status":"closed","ping_status":"closed","sticky":false,"template":"","format":"standard","meta":{"_coblocks_attr":"","_coblocks_dimensions":"","_coblocks_responsive_height":"","_coblocks_accordion_ie_support":"","_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[4442,56],"tags":[],"coauthors":[8612],"class_list":["post-154102","post","type-post","status-publish","format-standard","hentry","category-archive","category-bme-archive"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.5 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>ImpeedaSense Wearable Electrode Device - Senior Design Day<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.hajim.rochester.edu\/senior-design-day\/impeedasense-wearable-electrode-device\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ImpeedaSense Wearable Electrode Device - Senior Design Day\" \/>\n<meta property=\"og:description\" content=\"Problem Statement Falls experienced in hospitals are common and dangerous. Patients are at an especially high risk of experiencing a fall during trips to the bathroom [1]. Bladder bioimpedance can&hellip;\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.hajim.rochester.edu\/senior-design-day\/impeedasense-wearable-electrode-device\/\" \/>\n<meta property=\"og:site_name\" content=\"Senior Design Day\" \/>\n<meta property=\"article:published_time\" content=\"2024-05-02T15:13:59+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2025-05-02T18:44:34+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/lh7-us.googleusercontent.com\/lv0ysCdQD71JlcffNCZ1Lm4CS_dgdXSmQgnmE0MNSYTeFQkersDVDvqC60emvU2SG20kCFtdDFOHwy80vP2LkBlrHOnCE_kNrrn1SG-Kg_EP6-6VaY2yY0bYzjlfW54a8ndvnbY-qSMQJiM=s2048\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"5 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/impeedasense-wearable-electrode-device\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/impeedasense-wearable-electrode-device\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/#\\\/schema\\\/person\\\/351018fbcf84ed8cac6d8072ba5b347c\"},\"headline\":\"ImpeedaSense Wearable Electrode Device\",\"datePublished\":\"2024-05-02T15:13:59+00:00\",\"dateModified\":\"2025-05-02T18:44:34+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/impeedasense-wearable-electrode-device\\\/\"},\"wordCount\":702,\"image\":{\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/impeedasense-wearable-electrode-device\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/lh7-us.googleusercontent.com\\\/lv0ysCdQD71JlcffNCZ1Lm4CS_dgdXSmQgnmE0MNSYTeFQkersDVDvqC60emvU2SG20kCFtdDFOHwy80vP2LkBlrHOnCE_kNrrn1SG-Kg_EP6-6VaY2yY0bYzjlfW54a8ndvnbY-qSMQJiM=s2048\",\"articleSection\":[\"3. Programs Archive\",\"BME Archive\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/impeedasense-wearable-electrode-device\\\/\",\"url\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/impeedasense-wearable-electrode-device\\\/\",\"name\":\"ImpeedaSense Wearable Electrode Device - Senior Design Day\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/impeedasense-wearable-electrode-device\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/impeedasense-wearable-electrode-device\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/lh7-us.googleusercontent.com\\\/lv0ysCdQD71JlcffNCZ1Lm4CS_dgdXSmQgnmE0MNSYTeFQkersDVDvqC60emvU2SG20kCFtdDFOHwy80vP2LkBlrHOnCE_kNrrn1SG-Kg_EP6-6VaY2yY0bYzjlfW54a8ndvnbY-qSMQJiM=s2048\",\"datePublished\":\"2024-05-02T15:13:59+00:00\",\"dateModified\":\"2025-05-02T18:44:34+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/#\\\/schema\\\/person\\\/351018fbcf84ed8cac6d8072ba5b347c\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/impeedasense-wearable-electrode-device\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/impeedasense-wearable-electrode-device\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/impeedasense-wearable-electrode-device\\\/#primaryimage\",\"url\":\"https:\\\/\\\/lh7-us.googleusercontent.com\\\/lv0ysCdQD71JlcffNCZ1Lm4CS_dgdXSmQgnmE0MNSYTeFQkersDVDvqC60emvU2SG20kCFtdDFOHwy80vP2LkBlrHOnCE_kNrrn1SG-Kg_EP6-6VaY2yY0bYzjlfW54a8ndvnbY-qSMQJiM=s2048\",\"contentUrl\":\"https:\\\/\\\/lh7-us.googleusercontent.com\\\/lv0ysCdQD71JlcffNCZ1Lm4CS_dgdXSmQgnmE0MNSYTeFQkersDVDvqC60emvU2SG20kCFtdDFOHwy80vP2LkBlrHOnCE_kNrrn1SG-Kg_EP6-6VaY2yY0bYzjlfW54a8ndvnbY-qSMQJiM=s2048\"},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/impeedasense-wearable-electrode-device\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ImpeedaSense Wearable Electrode Device\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/#website\",\"url\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/\",\"name\":\"Senior Design Day\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/#\\\/schema\\\/person\\\/351018fbcf84ed8cac6d8072ba5b347c\",\"name\":\"admin\",\"url\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/author\\\/seniordesign\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ImpeedaSense Wearable Electrode Device - Senior Design Day","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/impeedasense-wearable-electrode-device\/","og_locale":"en_US","og_type":"article","og_title":"ImpeedaSense Wearable Electrode Device - Senior Design Day","og_description":"Problem Statement Falls experienced in hospitals are common and dangerous. Patients are at an especially high risk of experiencing a fall during trips to the bathroom [1]. Bladder bioimpedance can&hellip;","og_url":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/impeedasense-wearable-electrode-device\/","og_site_name":"Senior Design Day","article_published_time":"2024-05-02T15:13:59+00:00","article_modified_time":"2025-05-02T18:44:34+00:00","og_image":[{"url":"https:\/\/lh7-us.googleusercontent.com\/lv0ysCdQD71JlcffNCZ1Lm4CS_dgdXSmQgnmE0MNSYTeFQkersDVDvqC60emvU2SG20kCFtdDFOHwy80vP2LkBlrHOnCE_kNrrn1SG-Kg_EP6-6VaY2yY0bYzjlfW54a8ndvnbY-qSMQJiM=s2048","type":"","width":"","height":""}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Est. reading time":"5 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/impeedasense-wearable-electrode-device\/#article","isPartOf":{"@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/impeedasense-wearable-electrode-device\/"},"author":{"name":"admin","@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/#\/schema\/person\/351018fbcf84ed8cac6d8072ba5b347c"},"headline":"ImpeedaSense Wearable Electrode Device","datePublished":"2024-05-02T15:13:59+00:00","dateModified":"2025-05-02T18:44:34+00:00","mainEntityOfPage":{"@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/impeedasense-wearable-electrode-device\/"},"wordCount":702,"image":{"@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/impeedasense-wearable-electrode-device\/#primaryimage"},"thumbnailUrl":"https:\/\/lh7-us.googleusercontent.com\/lv0ysCdQD71JlcffNCZ1Lm4CS_dgdXSmQgnmE0MNSYTeFQkersDVDvqC60emvU2SG20kCFtdDFOHwy80vP2LkBlrHOnCE_kNrrn1SG-Kg_EP6-6VaY2yY0bYzjlfW54a8ndvnbY-qSMQJiM=s2048","articleSection":["3. Programs Archive","BME Archive"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/impeedasense-wearable-electrode-device\/","url":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/impeedasense-wearable-electrode-device\/","name":"ImpeedaSense Wearable Electrode Device - Senior Design Day","isPartOf":{"@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/impeedasense-wearable-electrode-device\/#primaryimage"},"image":{"@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/impeedasense-wearable-electrode-device\/#primaryimage"},"thumbnailUrl":"https:\/\/lh7-us.googleusercontent.com\/lv0ysCdQD71JlcffNCZ1Lm4CS_dgdXSmQgnmE0MNSYTeFQkersDVDvqC60emvU2SG20kCFtdDFOHwy80vP2LkBlrHOnCE_kNrrn1SG-Kg_EP6-6VaY2yY0bYzjlfW54a8ndvnbY-qSMQJiM=s2048","datePublished":"2024-05-02T15:13:59+00:00","dateModified":"2025-05-02T18:44:34+00:00","author":{"@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/#\/schema\/person\/351018fbcf84ed8cac6d8072ba5b347c"},"breadcrumb":{"@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/impeedasense-wearable-electrode-device\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.hajim.rochester.edu\/senior-design-day\/impeedasense-wearable-electrode-device\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/impeedasense-wearable-electrode-device\/#primaryimage","url":"https:\/\/lh7-us.googleusercontent.com\/lv0ysCdQD71JlcffNCZ1Lm4CS_dgdXSmQgnmE0MNSYTeFQkersDVDvqC60emvU2SG20kCFtdDFOHwy80vP2LkBlrHOnCE_kNrrn1SG-Kg_EP6-6VaY2yY0bYzjlfW54a8ndvnbY-qSMQJiM=s2048","contentUrl":"https:\/\/lh7-us.googleusercontent.com\/lv0ysCdQD71JlcffNCZ1Lm4CS_dgdXSmQgnmE0MNSYTeFQkersDVDvqC60emvU2SG20kCFtdDFOHwy80vP2LkBlrHOnCE_kNrrn1SG-Kg_EP6-6VaY2yY0bYzjlfW54a8ndvnbY-qSMQJiM=s2048"},{"@type":"BreadcrumbList","@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/impeedasense-wearable-electrode-device\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/"},{"@type":"ListItem","position":2,"name":"ImpeedaSense Wearable Electrode Device"}]},{"@type":"WebSite","@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/#website","url":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/","name":"Senior Design Day","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/#\/schema\/person\/351018fbcf84ed8cac6d8072ba5b347c","name":"admin","url":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/author\/seniordesign\/"}]}},"_links":{"self":[{"href":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-json\/wp\/v2\/posts\/154102","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-json\/wp\/v2\/users\/6242"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-json\/wp\/v2\/comments?post=154102"}],"version-history":[{"count":6,"href":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-json\/wp\/v2\/posts\/154102\/revisions"}],"predecessor-version":[{"id":170252,"href":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-json\/wp\/v2\/posts\/154102\/revisions\/170252"}],"wp:attachment":[{"href":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-json\/wp\/v2\/media?parent=154102"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-json\/wp\/v2\/categories?post=154102"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-json\/wp\/v2\/tags?post=154102"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-json\/wp\/v2\/coauthors?post=154102"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}