{"id":47642,"date":"2021-03-18T13:07:51","date_gmt":"2021-03-18T17:07:51","guid":{"rendered":"https:\/\/seniordesign.digitalscholar.rochester.edu\/ece2021\/?p=65"},"modified":"2022-04-13T10:49:07","modified_gmt":"2022-04-13T14:49:07","slug":"health-care-test-station","status":"publish","type":"post","link":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/health-care-test-station\/","title":{"rendered":"Health Care Test Station"},"content":{"rendered":"\n<p class=\"has-primary-color has-text-color has-larger-font-size\"><strong>Background<\/strong><\/p>\n\n\n\n<p>In many rural areas, there is a shortage of healthcare facilities and healthcare professionals. Many rural residents seeking care have to travel long distances to healthcare facilities. In U.S., the rural counties still make the higher percentage of the testing deserts even though the number of number of counties lacking testing sites are decreasing.<sup><a href=\"https:\/\/www.wsj.com\/articles\/covid-19-testing-challenges-remain-for-many-urban-rural-communities-11611320400?st=gbfezz0sy0if7ep&amp;reflink=desktopwebshare_permalink\">[1]<\/a><\/sup>  To control the spread of Covid-19, everyone needs to have an easy access to testing and treatment so that they can safely isolate.<\/p>\n\n\n\n<p class=\"has-larger-font-size\"><strong>Our Approach<\/strong><\/p>\n\n\n\n<p>We wanted to target the testing part of this problem. A healthcare test station is designed to facilitate in self-testing of Covid-19 and potential future diseases. This station will guide the users in conducting nasal swab test themselves without the observation of a healthcare professional using digital image processing. After each user, it will clean the interactive system using UVC lights. It will also collect and store test viles in a secure container until a healthcare worker can pick it up at the end of the day to take them to laboratory. So, our project has three main parts:<\/p>\n\n\n\n<ol class=\"wp-block-list\"><li>User Interface<\/li><li>Test Collection Unit<\/li><li>Disinfection Unit<\/li><\/ol>\n\n\n\n<p class=\"has-larger-font-size\"><strong>User Interface<\/strong><\/p>\n\n\n\n<p>The user interface will:<\/p>\n\n\n\n<ol class=\"wp-block-list\"><li>Collect personal information<ul><li>The name will be recorded in accordance with the test vial&#8217;s position in the storage unit <\/li><\/ul><\/li><li>Guide users through conducting the self testing correctly <ul><li>The USB camera will turn on <\/li><li>It will detect the user&#8217;s face, the tip of the user&#8217;s nose and it will also detect the green colored part of the nasal swab<\/li><\/ul><ul><li>With these two measurement above, it is able to calculate how much of the nasal swab is inserted into the user&#8217;s nose. It will give feedback to the customer accordingly (green color means that the test is conducted properly; the red color means that the swab needs to be inserted deeper)<\/li><\/ul><\/li><\/ol>\n\n\n\n<figure class=\"wp-block-video\"><video height=\"720\" style=\"aspect-ratio: 1280 \/ 720;\" width=\"1280\" controls src=\"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2021\/03\/User-interface-bad-1.mp4\"><\/video><figcaption><em>In this video, user ALAINA struggles to keep the swab at the right position and the interface guides her to insert the swab further<\/em><\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-video\"><video height=\"1335\" style=\"aspect-ratio: 945 \/ 1335;\" width=\"945\" controls src=\"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2021\/05\/User-Interface-video-1.mp4\"><\/video><figcaption><em>In this video, user ALAINA takes the test without issues and places the vial in the storage unit<\/em><\/figcaption><\/figure>\n\n\n\n<p class=\"has-larger-font-size\"><strong>Test Collection Unit<\/strong><\/p>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2021\/05\/Storage-Unit-1024x752.jpg\" alt=\"\" class=\"wp-image-1091\"\/><\/figure>\n\n\n\n<p>The user can put the nasal swab into a test vile after their self-testing is completed. They can place the test vile into the collection unit for safe keeping afterwards. The collection unit consists of:<\/p>\n\n\n\n<div class=\"wp-block-coblocks-accordion\">\n<div class=\"wp-block-coblocks-accordion-item\"><\/div>\n<\/div>\n\n\n\n<div class=\"wp-block-coblocks-accordion\">\n<div class=\"wp-block-coblocks-accordion-item\"><\/div>\n<\/div>\n\n\n\n<ol class=\"wp-block-list\"><li>A round test tube rack<\/li><li>Slotted optical switch (OPB880)<\/li><\/ol>\n\n\n\n<p><img decoding=\"async\" src=\"https:\/\/lh3.googleusercontent.com\/nw31DXAgd0GlAphFFRJiMGSTlxPW5op9b7oY-2OLPh-pC7-D7OXqg3k68gHPjrQCSwoaOpLt5P-gSyXr4QiUWhx9soaqwqDTQxnec7ovB6OabJHIlq_-ZpRlVwwrTj4sB9Oj7qY4\" style=\"width: undefinedpx;\"><\/p>\n\n\n\n<p>3. ULN2003 5V Stepper Motor 1<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Powered with a 5V USB wall connection<\/li><\/ul>\n\n\n\n<p>4. ULN2003 Driver Board<\/p>\n\n\n\n<p><img loading=\"lazy\" decoding=\"async\" width=\"561\" height=\"307\" src=\"https:\/\/lh3.googleusercontent.com\/vKafiQP5pcTXJe899lJJ4IB05__sOAD2--yZLtiPWUSl4kI1d1igU2RhYWugofR0slca_6HQz2dd1VkjGAcZo-p1HPqnmaUovUxdVVbZvfuGvPJj85o0MhGxW42L3hO1W1xuTLdz\"><\/p>\n\n\n\n<p>5. Stand<\/p>\n\n\n\n<p>After the user places the test vile into the round tube rack, the rack will rotate to the new slot controlled by Stepper Motor 1. The position of the slots are determined with the slotted optical switch. When the optical swith detects the next slot, the rotation will terminate.<\/p>\n\n\n\n<figure class=\"wp-block-video\"><video height=\"376\" style=\"aspect-ratio: 625 \/ 376;\" width=\"625\" controls src=\"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2021\/05\/Storage-Unit-video-1.mp4\"><\/video><\/figure>\n\n\n\n<p class=\"has-larger-font-size\"><strong>Disinfection Unit <\/strong><\/p>\n\n\n\n<p>The LCD touch screen will be cleaned after each user with UV lights. The UV lights are attached to a lead screw which will move over the surface of the station controlled by Stepper Motor 2. The cleaning unit consists of:<\/p>\n\n\n\n<ol class=\"wp-block-list\"><li>Lead screw<\/li><li>UV lights <\/li><\/ol>\n\n\n\n<ul class=\"wp-block-list\"><li>Powered with a 9V battery<\/li><li>Housed in a sheet metal cover<\/li><\/ul>\n\n\n\n<figure class=\"wp-block-image size-large\"><img decoding=\"async\" src=\"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2021\/05\/UV-lights-1.jpg\" alt=\"\" class=\"wp-image-1098\"\/><figcaption><img loading=\"lazy\" decoding=\"async\" width=\"607\" height=\"521\" src=\"https:\/\/lh5.googleusercontent.com\/D5Z0fCdGvHF5N0S6msSfF2DaDT_7wa9zdbbmnIP3RMgBg33VOpYjYSeqCPAvUjQhYt2lbk4x2d3WMGQ4Xj5oOeemJBJmPBCiH57GIT2KpDYknDJJVKwh6sOzri2J7yinGBL2W-Du\"><\/figcaption><\/figure>\n\n\n\n<p>3. ULN2003 5V Stepper Motor 2<\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Powered with a 5V USB wall connection<\/li><\/ul>\n\n\n\n<p>4. ULN2003 Driver Board<\/p>\n\n\n\n<p><img loading=\"lazy\" decoding=\"async\" width=\"546\" height=\"334\" src=\"https:\/\/lh5.googleusercontent.com\/bCySIK6P1xbX8PgKF2ucoDxs1bALqk3dTOqsihDtDpckCTSNEQMmGpC8F3WH92pOSv39mLIbfgVt_ATumpY6MVPCWQczMvqE1u6t1whZlmRJitWkrGW1B88-M6Z9RSG27JrRnYmk\"><\/p>\n\n\n\n<p>5. Limit switches 1 and 2<\/p>\n\n\n\n<p><img loading=\"lazy\" decoding=\"async\" src=\"https:\/\/lh4.googleusercontent.com\/yfMclSduC8akhUNs627tEqMVfNbvtPlPy4Mst849GLX8EpKkAYGxZM22maMGIRc1cL9WBEuW10-TqwxIgRWRXiyd21J-abqpjG1PAVA-jvyeSx4eoApCvUZiypduci-XgEYn9-6f\" width=\"623\" height=\"629\"><\/p>\n\n\n\n<figure class=\"wp-block-video\"><video height=\"666\" style=\"aspect-ratio: 452 \/ 666;\" width=\"452\" controls src=\"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2021\/03\/UV-Light-video-part1.mp4\"><\/video><figcaption><em>In this video, the UV light begins to sanitize the LCD screen moved by Stepper Motor 2.<\/em><\/figcaption><\/figure>\n\n\n\n<figure class=\"wp-block-video\"><video height=\"1080\" style=\"aspect-ratio: 1920 \/ 1080;\" width=\"1920\" controls src=\"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2021\/03\/UV-light-video-part2.mp4\"><\/video><figcaption><em>As the UV light reaches Limit Switch 1, it will turn around and return to it&#8217;s starting position<\/em><\/figcaption><\/figure>\n\n\n\n<p>Limit switches on either side mark how far the UV lights will move. After sanitizing the entire screen, the UV light will turn off and wait until the next user finishes their test.<\/p>\n\n\n\n<p class=\"has-larger-font-size\"><strong>Project Conclusion<\/strong><\/p>\n\n\n\n<p>Each unit was assembled and tested separately. At the end, we connected all three units together and worked successfully as a collective as well. <\/p>\n\n\n\n<div class=\"wp-block-columns is-layout-flex wp-container-core-columns-is-layout-9d6595d7 wp-block-columns-is-layout-flex\">\n<div class=\"wp-block-column is-layout-flow wp-block-column-is-layout-flow\" style=\"flex-basis:100%\">\n<p>All Circuit diagrams were made using circuit-diagram.org. <\/p>\n<\/div>\n<\/div>\n\n\n\n<p class=\"has-larger-font-size\"><strong>Future Improvements<\/strong><\/p>\n\n\n\n<p>Future designs could ask for more information such as date of test, birth-date, residence, COVID symptoms, or other user information deemed necessary. It can also be extended to data collection for different diseases. However, this along with aesthetic improvements are relatively minor adjustments. <\/p>\n\n\n\n<p>The image processing is highly dependent on lighting. It works best in natural, well-lit areas. Two ways to improve this for any space could be to provide a light source next to the camera or use a more sensitive camera.<\/p>\n\n\n\n<p>More importantly Stepper Motor 2, used to move the UVC lights, can get stuck while moving the lead screw. This is likely due to the alignment of the motor shaft and the lead screw. Given more time, this could be adjusted to run more smoothly. <\/p>\n\n\n\n<p>Stepper Motor 1, used to rotate the storage unit, is quite slow. This is not a dire issue because it does not have to move very far or very quickly; however, it could be improved upon to shorten setup time between user tests.<\/p>\n\n\n\n<p>Because the Raspberry Pi and the motors each have a wall connection, the system requires two functional outlets. In a future design, we could provide a built-in system outlet or an extension cord.<\/p>\n\n\n\n<p class=\"has-larger-font-size\"><strong>Team Members<\/strong><\/p>\n\n\n\n<ul class=\"wp-block-list\"><li>Alaina Attanasio<\/li><li>Andres Ayes<\/li><li>Asude Baykal<\/li><\/ul>\n\n\n\n<p class=\"has-larger-font-size\"><strong>Supervisors<\/strong><\/p>\n\n\n\n<p>Professor Jack Mottley<\/p>\n\n\n\n<p>Professor Daniel Phinney <\/p>\n","protected":false},"excerpt":{"rendered":"<p>A stationary unit designed to help facilitate the testing and storage of COVID-19 tests.<\/p>\n","protected":false},"author":6242,"featured_media":49382,"comment_status":"open","ping_status":"open","sticky":false,"template":"templates\/template-full-width.php","format":"standard","meta":{"_coblocks_attr":"","_coblocks_dimensions":"","_coblocks_responsive_height":"","_coblocks_accordion_ie_support":"","_monsterinsights_skip_tracking":false,"_monsterinsights_sitenote_active":false,"_monsterinsights_sitenote_note":"","_monsterinsights_sitenote_category":0,"footnotes":""},"categories":[3026,116,3016,2946],"tags":[],"coauthors":[8612],"class_list":["post-47642","post","type-post","status-publish","format-standard","has-post-thumbnail","hentry","category-accessibility-archive","category-ece-archive","category-global-health-archive","category-medical-archive"],"acf":[],"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.3 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Health Care Test Station - Senior Design Day<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.hajim.rochester.edu\/senior-design-day\/health-care-test-station\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Health Care Test Station - Senior Design Day\" \/>\n<meta property=\"og:description\" content=\"A stationary unit designed to help facilitate the testing and storage of COVID-19 tests.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.hajim.rochester.edu\/senior-design-day\/health-care-test-station\/\" \/>\n<meta property=\"og:site_name\" content=\"Senior Design Day\" \/>\n<meta property=\"article:published_time\" content=\"2021-03-18T17:07:51+00:00\" \/>\n<meta property=\"article:modified_time\" content=\"2022-04-13T14:49:07+00:00\" \/>\n<meta property=\"og:image\" content=\"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2021\/03\/20210506_144707-1-2.jpg\" \/>\n\t<meta property=\"og:image:width\" content=\"630\" \/>\n\t<meta property=\"og:image:height\" content=\"630\" \/>\n\t<meta property=\"og:image:type\" content=\"image\/jpeg\" \/>\n<meta name=\"author\" content=\"admin\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<meta name=\"twitter:label1\" content=\"Written by\" \/>\n\t<meta name=\"twitter:data1\" content=\"admin\" \/>\n\t<meta name=\"twitter:label2\" content=\"Est. reading time\" \/>\n\t<meta name=\"twitter:data2\" content=\"4 minutes\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\\\/\\\/schema.org\",\"@graph\":[{\"@type\":\"Article\",\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/health-care-test-station\\\/#article\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/health-care-test-station\\\/\"},\"author\":{\"name\":\"admin\",\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/#\\\/schema\\\/person\\\/351018fbcf84ed8cac6d8072ba5b347c\"},\"headline\":\"Health Care Test Station\",\"datePublished\":\"2021-03-18T17:07:51+00:00\",\"dateModified\":\"2022-04-13T14:49:07+00:00\",\"mainEntityOfPage\":{\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/health-care-test-station\\\/\"},\"wordCount\":856,\"commentCount\":0,\"image\":{\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/health-care-test-station\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/wp-content\\\/uploads\\\/2021\\\/03\\\/20210506_144707-1-2.jpg\",\"articleSection\":[\"Accessibility Archive\",\"ECE Archive\",\"Global Health Archive\",\"Medical Archive\"],\"inLanguage\":\"en-US\"},{\"@type\":\"WebPage\",\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/health-care-test-station\\\/\",\"url\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/health-care-test-station\\\/\",\"name\":\"Health Care Test Station - Senior Design Day\",\"isPartOf\":{\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/#website\"},\"primaryImageOfPage\":{\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/health-care-test-station\\\/#primaryimage\"},\"image\":{\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/health-care-test-station\\\/#primaryimage\"},\"thumbnailUrl\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/wp-content\\\/uploads\\\/2021\\\/03\\\/20210506_144707-1-2.jpg\",\"datePublished\":\"2021-03-18T17:07:51+00:00\",\"dateModified\":\"2022-04-13T14:49:07+00:00\",\"author\":{\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/#\\\/schema\\\/person\\\/351018fbcf84ed8cac6d8072ba5b347c\"},\"breadcrumb\":{\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/health-care-test-station\\\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/health-care-test-station\\\/\"]}]},{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/health-care-test-station\\\/#primaryimage\",\"url\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/wp-content\\\/uploads\\\/2021\\\/03\\\/20210506_144707-1-2.jpg\",\"contentUrl\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/wp-content\\\/uploads\\\/2021\\\/03\\\/20210506_144707-1-2.jpg\",\"width\":2516,\"height\":2516},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/health-care-test-station\\\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Health Care Test Station\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/#website\",\"url\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/\",\"name\":\"Senior Design Day\",\"description\":\"\",\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Person\",\"@id\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/#\\\/schema\\\/person\\\/351018fbcf84ed8cac6d8072ba5b347c\",\"name\":\"admin\",\"url\":\"https:\\\/\\\/www.hajim.rochester.edu\\\/senior-design-day\\\/author\\\/seniordesign\\\/\"}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Health Care Test Station - Senior Design Day","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/health-care-test-station\/","og_locale":"en_US","og_type":"article","og_title":"Health Care Test Station - Senior Design Day","og_description":"A stationary unit designed to help facilitate the testing and storage of COVID-19 tests.","og_url":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/health-care-test-station\/","og_site_name":"Senior Design Day","article_published_time":"2021-03-18T17:07:51+00:00","article_modified_time":"2022-04-13T14:49:07+00:00","og_image":[{"url":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2021\/03\/20210506_144707-1-2.jpg","width":630,"height":630,"type":"image\/jpeg"}],"author":"admin","twitter_card":"summary_large_image","twitter_misc":{"Written by":"admin","Est. reading time":"4 minutes"},"schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"Article","@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/health-care-test-station\/#article","isPartOf":{"@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/health-care-test-station\/"},"author":{"name":"admin","@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/#\/schema\/person\/351018fbcf84ed8cac6d8072ba5b347c"},"headline":"Health Care Test Station","datePublished":"2021-03-18T17:07:51+00:00","dateModified":"2022-04-13T14:49:07+00:00","mainEntityOfPage":{"@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/health-care-test-station\/"},"wordCount":856,"commentCount":0,"image":{"@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/health-care-test-station\/#primaryimage"},"thumbnailUrl":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2021\/03\/20210506_144707-1-2.jpg","articleSection":["Accessibility Archive","ECE Archive","Global Health Archive","Medical Archive"],"inLanguage":"en-US"},{"@type":"WebPage","@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/health-care-test-station\/","url":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/health-care-test-station\/","name":"Health Care Test Station - Senior Design Day","isPartOf":{"@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/#website"},"primaryImageOfPage":{"@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/health-care-test-station\/#primaryimage"},"image":{"@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/health-care-test-station\/#primaryimage"},"thumbnailUrl":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2021\/03\/20210506_144707-1-2.jpg","datePublished":"2021-03-18T17:07:51+00:00","dateModified":"2022-04-13T14:49:07+00:00","author":{"@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/#\/schema\/person\/351018fbcf84ed8cac6d8072ba5b347c"},"breadcrumb":{"@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/health-care-test-station\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.hajim.rochester.edu\/senior-design-day\/health-care-test-station\/"]}]},{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/health-care-test-station\/#primaryimage","url":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2021\/03\/20210506_144707-1-2.jpg","contentUrl":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-content\/uploads\/2021\/03\/20210506_144707-1-2.jpg","width":2516,"height":2516},{"@type":"BreadcrumbList","@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/health-care-test-station\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/"},{"@type":"ListItem","position":2,"name":"Health Care Test Station"}]},{"@type":"WebSite","@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/#website","url":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/","name":"Senior Design Day","description":"","potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Person","@id":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/#\/schema\/person\/351018fbcf84ed8cac6d8072ba5b347c","name":"admin","url":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/author\/seniordesign\/"}]}},"_links":{"self":[{"href":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-json\/wp\/v2\/posts\/47642","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-json\/wp\/v2\/posts"}],"about":[{"href":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-json\/wp\/v2\/types\/post"}],"author":[{"embeddable":true,"href":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-json\/wp\/v2\/users\/6242"}],"replies":[{"embeddable":true,"href":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-json\/wp\/v2\/comments?post=47642"}],"version-history":[{"count":1,"href":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-json\/wp\/v2\/posts\/47642\/revisions"}],"predecessor-version":[{"id":48732,"href":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-json\/wp\/v2\/posts\/47642\/revisions\/48732"}],"wp:featuredmedia":[{"embeddable":true,"href":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-json\/wp\/v2\/media\/49382"}],"wp:attachment":[{"href":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-json\/wp\/v2\/media?parent=47642"}],"wp:term":[{"taxonomy":"category","embeddable":true,"href":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-json\/wp\/v2\/categories?post=47642"},{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-json\/wp\/v2\/tags?post=47642"},{"taxonomy":"author","embeddable":true,"href":"https:\/\/www.hajim.rochester.edu\/senior-design-day\/wp-json\/wp\/v2\/coauthors?post=47642"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}