Jonathan Langdon wins Outstanding Dissertation Award for Engineering

May 5, 2016

jonCongratulations to graduate student Jonathan Langdon of the McAleavey Lab who received the prestigious Outstanding Dissertation Award for Engineering this year. This honor attests to Jonathan’s exceptional work in the field of biomedical ultrasound and comes with a monetary award of $1,000. His thesis was titled, “Development of Single Track Location Shear Wave Viscoelasticity Imaging for Real-Time Characterization of Biological Tissues.” 

"Jonathan was an outstanding PhD student in our biomedical engineering program,” said Diane Dalecki, director of the Rochester Center for Biomedical Ultrasound, and professor of biomedical engineering. “His dissertation research made significant advances in new ultrasound elastography technologies for measuring and visualizing viscoleastic properties of tissues. I am delighted to see Jonathan's work recognized with this award.”

The summary of Jonathan’s research project is below:

Development of Single Track Location Shear Wave Viscoelasticity Imaging for Real-Time Characterization of Biological Tissues


In response to chronic inflammation, many tissues undergo a transformation known as fibrosis that results in increased stiffness of the tissue. The parenchyma of the liver is one such tissue and may undergo fibrotic change as a result of a number of chronic diseases. The gold standard for monitoring the progression of chronic liver disease is biopsy. However, it is associated with a non-trivial morbidity. Therefore, non-invasive methods of assessing disease state are being sought. Elastography is a set of measurement methods that allow for the non-invasive estimation of tissue stiffness. Unfortunately, distinguishing between early stages of fibrosis has proven to be a challenge since a high level of measurement precision is required. Single Tracking Location Shear Wave Elasticity Imaging (STL-SWEI) is an elastography method that has been shown to improve measurement precision by compensating for speckle-induced bias. This method was previously investigated in the setting of liver fibrosis using a rat model. However, the precision of the measurements proved to be inadequate to distinguish the very earliest fibrosis stages. Additionally, it is unclear from the previous work that the Single Tracking Location per se is responsible for any measurement improvement. In this work, the STL-SWEI method is improved upon by introducing a real-time imaging software suite with matched implementations of both STL and Multiple Tracking Location (MTL) SWEI. Additionally, a novel viscoelastic estimator is implemented based on Maximum Likelihood Estimation theory. Third, a suite of graphic processing unit (GPU) accelerated simulation tools are introduced that allow for the simulation of SWEI images and exploration of the effects of boundary conditions on SWEI estimates. Finally, the ability of STL-SWEI to distinguish between stages of fibrosis in rat liver is re-evaluated using these new tools and directly compared to MTL-SWEI.